Application of bar adsorptive microextraction for the determination of levels of tricyclic antidepressants in urine samples

Mariana N. Oliveira, Oriana C. Gonçalves, Samir M. Ahmad, Jaderson K. Schneider, Laiza C. Krause, Nuno R. Neng, Elina B. Caramão, José M.F. Nogueira

Research output: Contribution to journalArticlepeer-review

10 Citations (Scopus)

Abstract

This work entailed the development, optimization, validation, and application of a novel analytical approach, using the bar adsorptive microextraction technique (BAμE), for the determination of the six most common tricyclic antidepressants (TCAs; amitriptyline, mianserin, trimipramine, imipramine, mirtazapine and dosulepin) in urine matrices. To achieve this goal, we employed, for the first time, new generation microextraction devices coated with convenient sorbent phases, polymers and novel activated carbons prepared from biomaterial waste, in combination with large-volume-injection gas chromatography-mass spectrometry operating in selected-ion monitoring mode (LVI-GC-MS(SIM)). Preliminary assays on sorbent coatings, showed that the polymeric phases present a much more effective performance, as the tested biosorbents exhibited low efficiency for application in microextraction techniques. By using BAμE coated with C18 polymer, under optimized experimental conditions, the detection limits achieved for the six TCAs ranged from 0.2 to 1.6 μg L-1 and, weighted linear regressions resulted in remarkable linearity (r2 > 0.9960) between 10.0 and 1000.0 μg L-1. The developed analytical methodology (BAμE(C18)/LVI-GC-MS(SIM)) provided suitable matrix effects (90.2-112.9%, RSD ≤ 13.9%), high recovery yields (92.3-111.5%, RSD ≤ 12.3%) and a remarkable overall process efficiency (ranging from 84.9% to 124.3%, RSD ≤ 13.9%). The developed and validated methodology was successfully applied for screening the six TCAs in real urine matrices. The proposed analytical methodology proved to be an eco-user-friendly approach to monitor trace levels of TCAs in complex urine matrices and an outstanding analytical alternative in comparison with other microextraction-based techniques.

Original languageEnglish
Article number3101
JournalMolecules
Volume26
Issue number11
DOIs
Publication statusPublished - 2021

Keywords

  • Bar adsorptive microextraction (BAμE)
  • Biomaterials waste
  • Flotation sampling technology
  • GC-MS
  • Novel sorbent phases
  • Tricyclic antidepressants
  • Urine samples

Fingerprint

Dive into the research topics of 'Application of bar adsorptive microextraction for the determination of levels of tricyclic antidepressants in urine samples'. Together they form a unique fingerprint.

Cite this