TY - JOUR
T1 - Complication Rates of Central Venous Catheters
T2 - A Systematic Review and Meta-Analysis
AU - Teja, Bijan
AU - Bosch, Nicholas A.
AU - Diep, Calvin
AU - Pereira, Tiago V.
AU - Mauricio, Paolo
AU - Sklar, Michael C.
AU - Sankar, Ashwin
AU - Wijeysundera, Harindra C.
AU - Saskin, Refik
AU - Walkey, Allan
AU - Wijeysundera, Duminda N.
AU - Wunsch, Hannah
N1 - Publisher Copyright:
© 2024 American Medical Association. All rights reserved.
PY - 2024/5/6
Y1 - 2024/5/6
N2 - Importance: Central venous catheters (CVCs) are commonly used but are associated with complications. Quantifying complication rates is essential for guiding CVC utilization decisions. Objective: To summarize current rates of CVC-associated complications. Data Sources: MEDLINE, Embase, CINAHL, and CENTRAL databases were searched for observational studies and randomized clinical trials published between 2015 to 2023. Study Selection: This study included English-language observational studies and randomized clinical trials of adult patients that reported complication rates of short-term centrally inserted CVCs and data for 1 or more outcomes of interest. Studies that evaluated long-term intravascular devices, focused on dialysis catheters not typically used for medication administration, or studied catheters placed by radiologists were excluded. Data Extraction and Synthesis: Two reviewers independently extracted data and assessed risk of bias. Bayesian random-effects meta-analysis was applied to summarize event rates. Rates of placement complications (events/1000 catheters with 95% credible interval [CrI]) and use complications (events/1000 catheter-days with 95% CrI) were estimated. Main Outcomes and Measures: Ten prespecified complications associated with CVC placement (placement failure, arterial puncture, arterial cannulation, pneumothorax, bleeding events requiring action, nerve injury, arteriovenous fistula, cardiac tamponade, arrhythmia, and delay of ≥1 hour in vasopressor administration) and 5 prespecified complications associated with CVC use (malfunction, infection, deep vein thrombosis [DVT], thrombophlebitis, and venous stenosis) were assessed. The composite of 4 serious complications (arterial cannulation, pneumothorax, infection, or DVT) after CVC exposure for 3 days was also assessed. Results: Of 11722 screened studies, 130 were included in the analyses. Seven of 15 prespecified complications were meta-analyzed. Placement failure occurred at 20.4 (95% CrI, 10.9-34.4) events per 1000 catheters placed. Other rates of CVC placement complications (per 1000 catheters) were arterial canulation (2.8; 95% CrI, 0.1-10), arterial puncture (16.2; 95% CrI, 11.5-22), and pneumothorax (4.4; 95% CrI, 2.7-6.5). Rates of CVC use complications (per 1000 catheter-days) were malfunction (5.5; 95% CrI, 0.6-38), infection (4.8; 95% CrI, 3.4-6.6), and DVT (2.7; 95% CrI, 1.0-6.2). It was estimated that 30.2 (95% CrI, 21.8-43.0) in 1000 patients with a CVC for 3 days would develop 1 or more serious complication (arterial cannulation, pneumothorax, infection, or DVT). Use of ultrasonography was associated with lower rates of arterial puncture (risk ratio [RR], 0.20; 95% CrI, 0.09-0.44; 13.5 events vs 68.8 events/1000 catheters) and pneumothorax (RR, 0.25; 95% CrI, 0.08-0.80; 2.4 events vs 9.9 events/1000 catheters). Conclusions and Relevance: Approximately 3% of CVC placements were associated with major complications. Use of ultrasonography guidance may reduce specific risks including arterial puncture and pneumothorax.
AB - Importance: Central venous catheters (CVCs) are commonly used but are associated with complications. Quantifying complication rates is essential for guiding CVC utilization decisions. Objective: To summarize current rates of CVC-associated complications. Data Sources: MEDLINE, Embase, CINAHL, and CENTRAL databases were searched for observational studies and randomized clinical trials published between 2015 to 2023. Study Selection: This study included English-language observational studies and randomized clinical trials of adult patients that reported complication rates of short-term centrally inserted CVCs and data for 1 or more outcomes of interest. Studies that evaluated long-term intravascular devices, focused on dialysis catheters not typically used for medication administration, or studied catheters placed by radiologists were excluded. Data Extraction and Synthesis: Two reviewers independently extracted data and assessed risk of bias. Bayesian random-effects meta-analysis was applied to summarize event rates. Rates of placement complications (events/1000 catheters with 95% credible interval [CrI]) and use complications (events/1000 catheter-days with 95% CrI) were estimated. Main Outcomes and Measures: Ten prespecified complications associated with CVC placement (placement failure, arterial puncture, arterial cannulation, pneumothorax, bleeding events requiring action, nerve injury, arteriovenous fistula, cardiac tamponade, arrhythmia, and delay of ≥1 hour in vasopressor administration) and 5 prespecified complications associated with CVC use (malfunction, infection, deep vein thrombosis [DVT], thrombophlebitis, and venous stenosis) were assessed. The composite of 4 serious complications (arterial cannulation, pneumothorax, infection, or DVT) after CVC exposure for 3 days was also assessed. Results: Of 11722 screened studies, 130 were included in the analyses. Seven of 15 prespecified complications were meta-analyzed. Placement failure occurred at 20.4 (95% CrI, 10.9-34.4) events per 1000 catheters placed. Other rates of CVC placement complications (per 1000 catheters) were arterial canulation (2.8; 95% CrI, 0.1-10), arterial puncture (16.2; 95% CrI, 11.5-22), and pneumothorax (4.4; 95% CrI, 2.7-6.5). Rates of CVC use complications (per 1000 catheter-days) were malfunction (5.5; 95% CrI, 0.6-38), infection (4.8; 95% CrI, 3.4-6.6), and DVT (2.7; 95% CrI, 1.0-6.2). It was estimated that 30.2 (95% CrI, 21.8-43.0) in 1000 patients with a CVC for 3 days would develop 1 or more serious complication (arterial cannulation, pneumothorax, infection, or DVT). Use of ultrasonography was associated with lower rates of arterial puncture (risk ratio [RR], 0.20; 95% CrI, 0.09-0.44; 13.5 events vs 68.8 events/1000 catheters) and pneumothorax (RR, 0.25; 95% CrI, 0.08-0.80; 2.4 events vs 9.9 events/1000 catheters). Conclusions and Relevance: Approximately 3% of CVC placements were associated with major complications. Use of ultrasonography guidance may reduce specific risks including arterial puncture and pneumothorax.
UR - http://www.scopus.com/inward/record.url?scp=85186875807&partnerID=8YFLogxK
U2 - 10.1001/jamainternmed.2023.8232
DO - 10.1001/jamainternmed.2023.8232
M3 - Article
C2 - 38436976
AN - SCOPUS:85186875807
SN - 2168-6106
VL - 184
SP - 474
EP - 482
JO - JAMA Internal Medicine
JF - JAMA Internal Medicine
IS - 5
ER -