TY - JOUR
T1 - High throughput bar adsorptive microextraction
T2 - A novel cost-effective tool for monitoring benzodiazepines in large number of biological samples
AU - Ahmad, S. M.
AU - Nogueira, J. M.F.
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2019/7/1
Y1 - 2019/7/1
N2 - In this work, we propose an innovative high throughput (HT) apparatus using the bar adsorptive microextraction (BAμE) technique, which enables the simultaneous enrichment of up to 100 samples. This novel configuration was combined with microliquid desorption and high-performance liquid chromatography-diode array detection to monitor trace levels of eight benzodiazepines (diazepam, prazepam, bromazepam, oxazepam, lorazepam, alprazolam, temazepam and loflazepate) in biological samples. The proposed methodology was fully developed, optimized and validated, resulting in suitable intraday and interday precision (RSD ≤ 15%), with recovery yields ranging from 33.0% to 104.5%. The lower limits of quantification were between 20.0 and 100.0 µg L−1, using 1.0 mL of urine and 0.5 mL of plasma or serum samples. The application of the proposed methodology to real matrices resulted in average sample preparation time of around 2 min per sample, demonstrating that it is user-friendly, cost-effective and a rapid decision-making tool, whenever large number of samples are involved.
AB - In this work, we propose an innovative high throughput (HT) apparatus using the bar adsorptive microextraction (BAμE) technique, which enables the simultaneous enrichment of up to 100 samples. This novel configuration was combined with microliquid desorption and high-performance liquid chromatography-diode array detection to monitor trace levels of eight benzodiazepines (diazepam, prazepam, bromazepam, oxazepam, lorazepam, alprazolam, temazepam and loflazepate) in biological samples. The proposed methodology was fully developed, optimized and validated, resulting in suitable intraday and interday precision (RSD ≤ 15%), with recovery yields ranging from 33.0% to 104.5%. The lower limits of quantification were between 20.0 and 100.0 µg L−1, using 1.0 mL of urine and 0.5 mL of plasma or serum samples. The application of the proposed methodology to real matrices resulted in average sample preparation time of around 2 min per sample, demonstrating that it is user-friendly, cost-effective and a rapid decision-making tool, whenever large number of samples are involved.
KW - Benzodiazepines
KW - Biological samples
KW - HPLC-DAD
KW - High throughput bar adsorptive microextraction (HT-BAμE)
KW - Simultaneous analysis of large number of samples
UR - http://www.scopus.com/inward/record.url?scp=85061730722&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2019.02.004
DO - 10.1016/j.talanta.2019.02.004
M3 - Article
C2 - 30952246
AN - SCOPUS:85061730722
SN - 0039-9140
VL - 199
SP - 195
EP - 202
JO - Talanta
JF - Talanta
ER -