TY - JOUR
T1 - Lead toxicity promotes autonomic dysfunction with increased chemoreceptor sensitivity
AU - Geraldes, Vera
AU - Carvalho, Mafalda
AU - Goncalves-Rosa, Nataniel
AU - Tavares, Cristiano
AU - Laranjo, Sérgio
AU - Rocha, Isabel
N1 - Publisher Copyright:
© 2016 Elsevier Inc.
PY - 2016/5/1
Y1 - 2016/5/1
N2 - Mortality and morbidity by toxic metals is an important issue of occupational health. Lead is an ubiquitous heavy metal in our environment despite having no physiological role in biological systems. Being an homeostatic controller is expected that the autonomic nervous system would show a degree of impairment in lead toxicity. In fact, sympathoexcitation associated to high blood pressure and tachypnea has been described together with baroreflex dysfunction. However, the mechanisms underlying the autonomic dysfunction and the interplay between baro- and chemoreflex are not yet fully clarified. The angiotensinogenic PVN-NTS axis (paraventricular nucleus of the hypothalamus - nucleus tractus solitarius axis) is a particularly important neuronal pathway that could be responsible for the autonomic dysfunction and the cardiorespiratory impairment in lead toxicity. Within the current work, we addressed in vivo, baro- and chemoreceptor reflex behaviour, before and after central angiotensin inhibition, in order to better understand the cardiorespiratory autonomic mechanisms underlying the toxic effects of long-term lead exposure. For that, arterial pressure, heart rate, respiratory rate, sympathetic and parasympathetic activity and baro- and chemoreceptor reflex profiles of anaesthetized young adult rats exposed to lead, from foetal period to adulthood, were evaluated. Results showed increased chemosensitivity together with baroreceptor reflex impairment, sympathetic over-excitation, hypertension and tachypnea. Chemosensitivity and sympathetic overexcitation were reversed towards normality values by NTS treatment with A-779, an angiotensin (1-7) antagonist. No parasympathetic changes were observed before and after A-799 treatment. In conclusion, angiotensin (1-7) at NTS level is involved in the autonomic dysfunction observed in lead toxicity. The increased sensitivity of chemoreceptor reflex expresses the clear impairment of autonomic outflow to the cardiovascular and respiratory systems induced by putative persistent, long duration, alert reaction evoked by the long term exposure to lead toxic effects. The present study brings new insights on the central mechanisms implicated in the autonomic dysfunction induced by lead exposure which are relevant for the development of additional therapeutic options to tackle lead toxicity symptoms.
AB - Mortality and morbidity by toxic metals is an important issue of occupational health. Lead is an ubiquitous heavy metal in our environment despite having no physiological role in biological systems. Being an homeostatic controller is expected that the autonomic nervous system would show a degree of impairment in lead toxicity. In fact, sympathoexcitation associated to high blood pressure and tachypnea has been described together with baroreflex dysfunction. However, the mechanisms underlying the autonomic dysfunction and the interplay between baro- and chemoreflex are not yet fully clarified. The angiotensinogenic PVN-NTS axis (paraventricular nucleus of the hypothalamus - nucleus tractus solitarius axis) is a particularly important neuronal pathway that could be responsible for the autonomic dysfunction and the cardiorespiratory impairment in lead toxicity. Within the current work, we addressed in vivo, baro- and chemoreceptor reflex behaviour, before and after central angiotensin inhibition, in order to better understand the cardiorespiratory autonomic mechanisms underlying the toxic effects of long-term lead exposure. For that, arterial pressure, heart rate, respiratory rate, sympathetic and parasympathetic activity and baro- and chemoreceptor reflex profiles of anaesthetized young adult rats exposed to lead, from foetal period to adulthood, were evaluated. Results showed increased chemosensitivity together with baroreceptor reflex impairment, sympathetic over-excitation, hypertension and tachypnea. Chemosensitivity and sympathetic overexcitation were reversed towards normality values by NTS treatment with A-779, an angiotensin (1-7) antagonist. No parasympathetic changes were observed before and after A-799 treatment. In conclusion, angiotensin (1-7) at NTS level is involved in the autonomic dysfunction observed in lead toxicity. The increased sensitivity of chemoreceptor reflex expresses the clear impairment of autonomic outflow to the cardiovascular and respiratory systems induced by putative persistent, long duration, alert reaction evoked by the long term exposure to lead toxic effects. The present study brings new insights on the central mechanisms implicated in the autonomic dysfunction induced by lead exposure which are relevant for the development of additional therapeutic options to tackle lead toxicity symptoms.
KW - A-779
KW - Baroreceptor reflex
KW - Chemoreceptor reflex
KW - Hypertension
KW - Lead toxicity
KW - PVN-NTS axis
KW - Sympathoexcitation
UR - http://www.scopus.com/inward/record.url?scp=84966430301&partnerID=8YFLogxK
U2 - 10.1016/j.neuro.2016.04.016
DO - 10.1016/j.neuro.2016.04.016
M3 - Article
C2 - 27133440
AN - SCOPUS:84966430301
SN - 0161-813X
VL - 54
SP - 170
EP - 177
JO - NeuroToxicology
JF - NeuroToxicology
ER -