Multi-spheres adsorptive microextraction (MSAµE)—Application of a novel analytical approach for monitoring chemical anthropogenic markers in environmental water matrices

Ana R.M. Silva, Nuno R. Neng, José M.F. Nogueira

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Multi-spheres adsorptive microextraction using powdered activated carbons (ACs) was studied as a novel enrichment approach, followed by liquid desorption and high-performance liquid chromatography with diode array detection (MSAµE(AC)-LD/HPLC-DAD) to monitor caffeine (CAF) and acetaminophen (ACF) traces in environmental matrices. In this study, commercial activated carbons (N, NOX, and R) were tested, with the latter showing a much better performance for the analysis of both anthropogenic drugs. The main parameters affecting the efficiency of the proposed methodology are fully discussed using commercial AC(R). Textural and surface chemistry properties of the ACs sample were correlated with the analytical results. Assays performed on 30 mL of water samples spiked at 10 µg L1 under optimized experimental conditions, yielding recoveries of 75.3% for ACF and 82.6% for CAF. The methodology also showed excellent linear dynamic ranges for both drugs with determination coefficients higher than 0.9976, limits of detection and quantification of 0.8–1.2 µg L1 and 2.8–4.0 µg L1, respectively, and suitable precision (RSD < 13.8%). By using the standard addition method, the application of the present method to environmental matrices, including superficial, sea, and wastewater samples, allowed very good performance at the trace level. The proposed methodology proved to be a feasible alternative for polar compound analysis, showing to be easy to implement, reliable, and sensitive, with the possibility to reuse and store the analytical devices loaded with the target compounds for later analysis.

Original languageEnglish
Article number931
JournalMolecules
Volume24
Issue number5
DOIs
Publication statusPublished - 2019
Externally publishedYes

Keywords

  • Caffeine and acetaminophen tracers
  • Environmental water matrices
  • Floating sampling technology
  • Multi-spheres adsorptive micro-extraction (MSAµE)
  • Sorbent-based techniques

Fingerprint

Dive into the research topics of 'Multi-spheres adsorptive microextraction (MSAµE)—Application of a novel analytical approach for monitoring chemical anthropogenic markers in environmental water matrices'. Together they form a unique fingerprint.

Cite this