TY - JOUR
T1 - Validated method for the determination of misoprostol acid in whole blood by ultra performance liquid chromatography-tandem mass spectrometry
AU - Simões, Susana Sadler
AU - Ajenjo, Antonio Castañera
AU - Dias, Mário João
PY - 2012/12
Y1 - 2012/12
N2 - Misoprostol is a pharmaceutical synthetic compound, analog of prostaglandin E1, frequently used as an abortifacient in not medically supervised or self-induced abortions, particularly in countries with restrictive abortion laws representing a serious public health problem. The aim of this study was to develop and validate a sensitive analytical method for the determination of misoprostol acid in whole blood samples. The samples were prepared by SPE and the chromatographic separation was performed by UPLC-MS/MS using ESI- and MRM mode with an Acquity UPLC® BEH C18 (50mm×2.1mm i.d., 1.7μm) column using a methanol-ammonium 0.1% solution gradient in a total run time of 7.0min. The method showed to be selective and linear in range 25-2000ng/L. The LOD and LOQ were 10ng/L and 25ng/L, respectively. The recovery ranged from 89 to 97%. No carryover and significant matrix effect were observed. The intra- and inter-assay precisions and the inter-assay accuracy results were 4.0% and 5.4%, 5.5% and 4.1%, and -1.4% and -2.8%, for the concentrations 50 and 500ng/L, respectively. The method developed allows the analysis of misoprostol acid in whole blood samples with adequate sensitivity to the concentration range obtained from therapeutic doses. The method was successfully used in a controlled misoprostol administration study and has been applied in our laboratory in the forensic toxicology field.
AB - Misoprostol is a pharmaceutical synthetic compound, analog of prostaglandin E1, frequently used as an abortifacient in not medically supervised or self-induced abortions, particularly in countries with restrictive abortion laws representing a serious public health problem. The aim of this study was to develop and validate a sensitive analytical method for the determination of misoprostol acid in whole blood samples. The samples were prepared by SPE and the chromatographic separation was performed by UPLC-MS/MS using ESI- and MRM mode with an Acquity UPLC® BEH C18 (50mm×2.1mm i.d., 1.7μm) column using a methanol-ammonium 0.1% solution gradient in a total run time of 7.0min. The method showed to be selective and linear in range 25-2000ng/L. The LOD and LOQ were 10ng/L and 25ng/L, respectively. The recovery ranged from 89 to 97%. No carryover and significant matrix effect were observed. The intra- and inter-assay precisions and the inter-assay accuracy results were 4.0% and 5.4%, 5.5% and 4.1%, and -1.4% and -2.8%, for the concentrations 50 and 500ng/L, respectively. The method developed allows the analysis of misoprostol acid in whole blood samples with adequate sensitivity to the concentration range obtained from therapeutic doses. The method was successfully used in a controlled misoprostol administration study and has been applied in our laboratory in the forensic toxicology field.
KW - LC-MS/MS
KW - Misoprostol acid
KW - Stability
KW - Validation
KW - Whole blood
UR - http://www.scopus.com/inward/record.url?scp=84866750364&partnerID=8YFLogxK
U2 - 10.1016/j.jpba.2012.08.005
DO - 10.1016/j.jpba.2012.08.005
M3 - Article
C2 - 22940267
AN - SCOPUS:84866750364
SN - 0731-7085
VL - 71
SP - 198
EP - 201
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
ER -