TY - JOUR
T1 - Bar adsorptive microextraction (BAμE) coated with mixed sorbent phases-Enhanced selectivity for the determination of non-steroidal anti-inflammatory drugs in real matrices in combination with capillary electrophoresis
AU - Ahmad, S. M.
AU - Almeida, C.
AU - Neng, N. R.
AU - Nogueira, J. M.F.
N1 - Publisher Copyright:
© 2015 Elsevier B.V.
PY - 2016/1/1
Y1 - 2016/1/1
N2 - The present work proposes the application of bar adsorptive microextraction coated with mixed sorbent phases (n-vinylpyrrolidone and divinylbenzene polymers with strong and weak anion exchangers), combined with liquid desorption followed by capillary electrophoresis with diode array detection (BAμE(PMIX)-LD/CE-DAD) for the determination of trace levels of non-steroidal anti-inflammatory drugs (NSAIDs: salicylic acid, mefenamic acid, diclofenac and naproxen as model compounds) in urine and water matrices. Assays performed on 25mL of water samples spiked at the 80.0μg/L level, yielded average recoveries between 86.6 and 104.% for all the NSAIDs under study using optimized experimental conditions. The proposed analytical methodology demonstrated suitable detection limits (0.3μg/L) and good linear dynamic ranges (2.5-320.0μg/L) with determination coefficients higher than 0.9981. By using the standard addition methodology, the present analytical approach was applied on urine and water samples, where good selectivity and sensitivity were achieved. The proposed method, which operated under the floating sampling technology, proved to be a suitable sorption-based static microextraction alternative for monitoring trace levels of NSAIDs in urine and water samples. The methodology showed to be easy to implement, demonstrating good reproducibility and robustness, allowing the possibility to choose the most selective sorbent, or mixed sorbent phases, according to the compounds of interest.
AB - The present work proposes the application of bar adsorptive microextraction coated with mixed sorbent phases (n-vinylpyrrolidone and divinylbenzene polymers with strong and weak anion exchangers), combined with liquid desorption followed by capillary electrophoresis with diode array detection (BAμE(PMIX)-LD/CE-DAD) for the determination of trace levels of non-steroidal anti-inflammatory drugs (NSAIDs: salicylic acid, mefenamic acid, diclofenac and naproxen as model compounds) in urine and water matrices. Assays performed on 25mL of water samples spiked at the 80.0μg/L level, yielded average recoveries between 86.6 and 104.% for all the NSAIDs under study using optimized experimental conditions. The proposed analytical methodology demonstrated suitable detection limits (0.3μg/L) and good linear dynamic ranges (2.5-320.0μg/L) with determination coefficients higher than 0.9981. By using the standard addition methodology, the present analytical approach was applied on urine and water samples, where good selectivity and sensitivity were achieved. The proposed method, which operated under the floating sampling technology, proved to be a suitable sorption-based static microextraction alternative for monitoring trace levels of NSAIDs in urine and water samples. The methodology showed to be easy to implement, demonstrating good reproducibility and robustness, allowing the possibility to choose the most selective sorbent, or mixed sorbent phases, according to the compounds of interest.
KW - Bar adsorptive microextraction (BAμE)
KW - Capillary electrophoresis
KW - Environmental and biological samples
KW - Floating sampling technology
KW - Mixed sorbent phases
KW - Non-steroidal anti-inflammatory drugs
UR - http://www.scopus.com/inward/record.url?scp=84948799077&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2015.11.018
DO - 10.1016/j.jchromb.2015.11.018
M3 - Article
C2 - 26638036
AN - SCOPUS:84948799077
SN - 1570-0232
VL - 1008
SP - 115
EP - 124
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
ER -