TY - JOUR
T1 - Flow-mediated slowing shows poor repeatability compared with flow-mediated dilation in non-invasive assessment of brachial artery endothelial function
AU - Marôco, João Luís
AU - Pinto, Marco
AU - Santa-Clara, Helena
AU - Fernhall, Bo
AU - Melo, Xavier
N1 - Publisher Copyright:
This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 public domain dedication.
PY - 2022/5
Y1 - 2022/5
N2 - Pulse wave velocity (PWV) deceleration to reactive hyperemia–flow-mediated slowing (FMS)–has been suggested as an alternative method to flow-mediated dilation (FMD) to evaluate brachial artery endothelial function. FMS is suggested to address major caveats of the FMD procedure including its suboptimal repeatability and high-operator dependency. However, the repeatability of FMS has not been thoroughly examined, especially given the plethora of methods claiming to measure PWV. We assessed and compared the intra- and inter-day repeatability of FMS as measured by piezoelectric pressure mechanotransducers placed in the carotid and radial arteries, and brachial artery FMD as measured by echo-tracking. Twenty-four healthy male participants aged 23–75 yr, were examined on three separate days to assess intra and inter-day repeatability. All FMD and FMS examinations were conducted simultaneously by the same researcher complying with standardized guidelines. Repeatability was examined with intraclass correlation coefficient (ICC; >0.80), coefficient of variation (CV; <15%), and limits of agreement (95% LOA). Relative (%) FMD and FMS were scaled for baseline brachial artery diameter and PWV, respectively. Intra- (ICC: 0.72; CV: 136%; 95% LOA: -19.38 to 29.19%) and Inter-day (ICC: 0.69; CV: 145%, 95% LOA: -49.50 to 46.08%) repeatability of %FMS was poor, whereas %FMD demonstrated moderate-to-good intra- (ICC: 0.93; CV: 18%, 95% LOA: -3.02 to 3.75%) and inter-day repeatability (ICC: 0.74; CV: 25%, 95% LOA: -9.16 to 7.04%). Scaling FMD reduced the intra-day CV (-5%), and the uncertainty of the 95% LOA (- 37.64 to 35.69%) estimates of FMS. Carotid-radial artery FMS showed poorer repeatability compared to FMD.
AB - Pulse wave velocity (PWV) deceleration to reactive hyperemia–flow-mediated slowing (FMS)–has been suggested as an alternative method to flow-mediated dilation (FMD) to evaluate brachial artery endothelial function. FMS is suggested to address major caveats of the FMD procedure including its suboptimal repeatability and high-operator dependency. However, the repeatability of FMS has not been thoroughly examined, especially given the plethora of methods claiming to measure PWV. We assessed and compared the intra- and inter-day repeatability of FMS as measured by piezoelectric pressure mechanotransducers placed in the carotid and radial arteries, and brachial artery FMD as measured by echo-tracking. Twenty-four healthy male participants aged 23–75 yr, were examined on three separate days to assess intra and inter-day repeatability. All FMD and FMS examinations were conducted simultaneously by the same researcher complying with standardized guidelines. Repeatability was examined with intraclass correlation coefficient (ICC; >0.80), coefficient of variation (CV; <15%), and limits of agreement (95% LOA). Relative (%) FMD and FMS were scaled for baseline brachial artery diameter and PWV, respectively. Intra- (ICC: 0.72; CV: 136%; 95% LOA: -19.38 to 29.19%) and Inter-day (ICC: 0.69; CV: 145%, 95% LOA: -49.50 to 46.08%) repeatability of %FMS was poor, whereas %FMD demonstrated moderate-to-good intra- (ICC: 0.93; CV: 18%, 95% LOA: -3.02 to 3.75%) and inter-day repeatability (ICC: 0.74; CV: 25%, 95% LOA: -9.16 to 7.04%). Scaling FMD reduced the intra-day CV (-5%), and the uncertainty of the 95% LOA (- 37.64 to 35.69%) estimates of FMS. Carotid-radial artery FMS showed poorer repeatability compared to FMD.
UR - http://www.scopus.com/inward/record.url?scp=85131017771&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0267287
DO - 10.1371/journal.pone.0267287
M3 - Article
C2 - 35609038
AN - SCOPUS:85131017771
SN - 1932-6203
VL - 17
JO - PLoS ONE
JF - PLoS ONE
IS - 5 May
M1 - e0267287
ER -