Measuring Minerals in Pseudocereals Using Inductively Coupled Plasma Optical Emission Spectrometry: What Is the Optimal Digestion Method?

Ana C. Nascimento, Carla Motta, Andreia Rego, Inês Delgado, Susana Santiago, Ricardo Assunção, Ana Sofia Matos, Mariana Santos, Isabel Castanheira

Resultado de pesquisa: ???type-name??????researchoutput.researchoutputtypes.contributiontojournal.article???revisão de pares

1 Citação (Scopus)

Resumo

Pseudocereals have gained attention due to their adaptability to different climates, high nutritional value, and suitability for gluten-free and plant-based diets. However, a challenge lies in the necessary adaptations in the diet pathways, mainly due to the lack of matrix-matching metrological tools. To address this problem, we developed a classification system to support laboratory decisions without shaped Proficiency Testing (PT) or Certified/Standard References Material. This system evaluates method performance through limit of detection (LOD), maximum uncertainty, and statistical comparison. For that matter, the mineral contents (Cu, Mn, Fe, Zn, Mg, P, Ca, K, and Na) of quinoa (Chenopodium quinoa), amaranth (Amaranthus caudatus), and buckwheat (Fagopyrum esculentum) were determined, using three different digestion methods, including dry-ashing, microwave, and graphite block acid digestion. A decision was reached concerning the optimal digestion method to be employed, with the results classified into three categories: (i) “rejected if results failed in two categories; (ii) “use with caution” if results were not satisfactory in one category; or (iii) “accepted”, if the results passed in all the categories. The system efficacy was exemplified by the effectiveness of dry-ashing and graphite block acid digestion by comparison with microwave digestion. Neither dry-ashing nor graphite block acid digestion can be recommended as an alternative method to the microwave digestion method when all the prioritized nutrient minerals are understudied. Although the microwave method is preferable for multi-elemental analysis, it is possible to obtain, with caution, comparable results from all the digestion methods if a higher relative combined uncertainty is defined (target uncertainty < 11%) under the assumption that this is suitable for the study.

Idioma original???core.languages.en_GB???
Número do artigo565
RevistaFoods
Volume14
Número de emissão4
DOIs
Estado da publicação???researchoutput.status.published??? - fev. 2025

Impressão digital

Mergulhe nos tópicos de investigação de “Measuring Minerals in Pseudocereals Using Inductively Coupled Plasma Optical Emission Spectrometry: What Is the Optimal Digestion Method?“. Em conjunto formam uma impressão digital única.

Citar isto