TY - JOUR
T1 - Optimisation of stir bar sorptive extraction and liquid desorption combined with large volume injection-gas chromatography-quadrupole mass spectrometry for the determination of volatile compounds in wines
AU - Coelho, Elisabete
AU - Perestrelo, Rosa
AU - Neng, Nuno R.
AU - Câmara, José S.
AU - Coimbra, Manuel A.
AU - Nogueira, J. M.F.
AU - Rocha, Sílvia M.
N1 - Funding Information:
This work was financially supported by AGRO N° 38 and Fundação para a Ciência e a Tecnologia (SFRH/BD/25336/2005).
PY - 2008/8/22
Y1 - 2008/8/22
N2 - Stir bar sorptive extraction and liquid desorption followed by large volume injection coupled to gas chromatography-quadrupole mass spectrometry (SBSE-LD/LVI-GC-qMS) had been applied for the determination of volatiles in wines. The methodology was optimised in terms of extraction time and influence of ethanol in the matrix; LD conditions, and instrumental settings. The optimisation was carried out by using 10 standards representative of the main chemical families of wine, i.e. guaiazulene, E,E-farnesol, β-ionone, geranylacetone, ethyl decanoate, β-citronellol, 2-phenylethanol, linalool, hexyl acetate and hexanol. The methodology shows good linearity over the concentration range tested, with correlation coefficients higher than 0.9821, a good reproducibility was attained (8.9-17.8%), and low detection limits were achieved for nine volatile compounds (0.05-9.09 μg L-1), with the exception of 2-phenylethanol due to low recovery by SBSE. The analytical ability of the SBSE-LD/LVI-GC-qMS methodology was tested in real matrices, such as sparkling and table wines using analytical curves prepared by using the 10 standards where each one was applied to quantify the structurally related compounds. This methodology allowed, in a single run, the quantification of 67 wine volatiles at levels lower than their respective olfactory thresholds. The proposed methodology demonstrated to be easy to work-up, reliable, sensitive and with low sample requirement to monitor the volatile fraction of wine.
AB - Stir bar sorptive extraction and liquid desorption followed by large volume injection coupled to gas chromatography-quadrupole mass spectrometry (SBSE-LD/LVI-GC-qMS) had been applied for the determination of volatiles in wines. The methodology was optimised in terms of extraction time and influence of ethanol in the matrix; LD conditions, and instrumental settings. The optimisation was carried out by using 10 standards representative of the main chemical families of wine, i.e. guaiazulene, E,E-farnesol, β-ionone, geranylacetone, ethyl decanoate, β-citronellol, 2-phenylethanol, linalool, hexyl acetate and hexanol. The methodology shows good linearity over the concentration range tested, with correlation coefficients higher than 0.9821, a good reproducibility was attained (8.9-17.8%), and low detection limits were achieved for nine volatile compounds (0.05-9.09 μg L-1), with the exception of 2-phenylethanol due to low recovery by SBSE. The analytical ability of the SBSE-LD/LVI-GC-qMS methodology was tested in real matrices, such as sparkling and table wines using analytical curves prepared by using the 10 standards where each one was applied to quantify the structurally related compounds. This methodology allowed, in a single run, the quantification of 67 wine volatiles at levels lower than their respective olfactory thresholds. The proposed methodology demonstrated to be easy to work-up, reliable, sensitive and with low sample requirement to monitor the volatile fraction of wine.
KW - Gas chromatography-quadrupole mass spectrometry
KW - Large volume injection
KW - Liquid desorption
KW - Stir bar sorptive extraction
KW - Volatile compounds
KW - Wine
UR - http://www.scopus.com/inward/record.url?scp=48949098435&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2008.06.032
DO - 10.1016/j.aca.2008.06.032
M3 - Article
C2 - 18706312
AN - SCOPUS:48949098435
SN - 0003-2670
VL - 624
SP - 79
EP - 89
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
IS - 1
ER -