Vascular lesions and vibroacoustic disease

José Martins Dos Santos, Nuno R. Grande, Nuno A. Castelo Branco, Carlos Zagalo, Pedro Oliveira

Resultado de pesquisa: ???type-name??????researchoutput.researchoutputtypes.contributiontojournal.article???revisão de pares

28 Citações (Scopus)

Resumo

Low frequency noise (LFN) (≥ 90 dB SPL, ≤ 500 Hz) is an agent of disease that regularly goes unchecked during standard noise assessment procedures. Vibroacoustic disease (VAD) is an extra-aural noise-induced systemic pathology, caused by long-term exposure to LFN and characterised by a proliferation of extra-cellular matrices. The present study attempts to elucidate the behaviour of medium-and large-calibre blood vessels in the presence of insult due to noise and vibration. Thirty-five adult Wistar rats were studied. The animals were divided into 3 groups. One group of 20 rats was exposed to large pressure amplitude and low frequency (LPALF) noise in an occupationally simulated schedule: 8 h/day, 5 days/week, and weekends in silence, for 968 to 1984 (median 1576 h) cumulative hours of noise exposure. Another group of 5 rats was exposed to 24 h of continuous noise. The last group of 10 rats (control) was kept under identical conditions but in a silent environment. Overall noise levels were recorded above 109 dB, the A-weighted levels being around 98 dB (A). The rats were sacrificed and fragments of aorta, inferior vena cava and femoral artery and vein from both hindlimbs, were collected; these were prepared for histological examination. With long-term exposure, the aorta and the femoral artery showed a focal thickening of the intima, disruption of the internal elastic lamina and a proliferation of smooth muscle cells in the intima in 70% of the cases. With acute exposure, the lesions appeared in 60% of the cases observed. Most of the lesions involved the appearance of clefts in the media, pulling the cells and the elastic membranes apart. The media thickness-to-inner caliber ratio of the femoral artery was increased (p<0.05). Our results point to a remodelling of the vessels that can be attributed to vibration and flow disturbances. The observed remodelling was not observed in small vessels.

Idioma original???core.languages.en_GB???
Páginas (de-até)17-21
Número de páginas5
RevistaEuropean Journal of Anatomy
Volume6
Número de emissão1
Estado da publicação???researchoutput.status.published??? - mai. 2002

Impressão digital

Mergulhe nos tópicos de investigação de “Vascular lesions and vibroacoustic disease“. Em conjunto formam uma impressão digital única.

Citar isto